Delta VFD-M Motor Drives: Ratings, Models and Installation
Compare VFD-M ordering codes using the motor-side current rating and the required supply. Find verified model references and the relevant manufacturer manuals below.
- VFD004M21A
- VFD004M23A
- VFD007M21A
- VFD007M23A
- VFD007M43B
- VFD015M21A
- VFD015M43B
- VFD022M21A
- VFD022M43B
- VFD037M43A
- VFD055M43A
- VFD075M43A
A VFD-M capacity code does not tell you the whole electrical configuration. In Delta’s English manual, VFD007M23A is rated at 5.0 A output, while VFD007M43B is rated at 3.0 A. Both contain “007,” but they belong to different supply-voltage groups.
WOOLARS accepts Delta VFD-M drive inquiries. Use the complete model references below to identify your required configuration and compare the relevant rating against the motor nameplate.
Model references and rated output current
The values below are motor-side rated output current from the manufacturer’s English manual. They are not input-current values or short-duration overload allowances.
230 V model references
| Complete model | Rated output current (A) |
|---|---|
| VFD004M21A | 2.5 |
| VFD004M23A | 2.5 |
| VFD007M21A | 5.0 |
| VFD007M23A | 5.0 |
| VFD015M21A | 7.0 |
| VFD015M23A | 7.0 |
| VFD022M21A | 10 |
| VFD022M23A | Not stated here — see note |
| VFD037M23A | 17 |
| VFD055M23A | 25 |
460 V model references
| Complete model | Rated output current (A) |
|---|---|
| VFD004M43B | Not stated here — see note |
| VFD007M43B | 3.0 |
| VFD015M43B | 4.0 |
| VFD022M43B | 5.0 |
| VFD037M43A | 8.2 |
| VFD055M43A | 13 |
| VFD075M43A | 18 |
Source scope: the English VFD-M manual, revision August 2015, ME16, SW V3.13, supports the current entries. The Chinese VFD-M manual explicitly lists VFD004M43B and VFD022M23A under P80, but those exact codes are absent from the English edition reviewed here. Their identity is supported; no current value has been assigned to them in this table.
What does the supply version change?
The 21A versions listed here are single-phase 230 V-class models; 23A versions are three-phase 230 V-class models. The listed 43A/43B references belong to the three-phase 460 V class. These classes identify the supply group, not the full permitted operating range.
VFD004M21A and VFD004M23A each have a listed 2.5 A output rating. The matching output value does not remove their input-phase distinction. Conversely, the 007 example above shows that the same capacity prefix across voltage classes can have different output-current values.
For a purchasing comparison, keep the supply configuration and motor voltage/current together. Review the load’s operating pattern and the applicable rating conditions before accepting a proposed alternative.
Read installation conditions with the rating
The English manual lists an operating ambient range of -10 to 40°C, with -10 to 50°C stated for the configuration without the blind plate. It also specifies an installation altitude of 1,000 m or lower. The higher temperature figure must not be treated as an unconditional rating for every enclosure arrangement.
Use the manual’s installation and dimension sections for the actual unit. Record any cabinet changes when replacing a drive: airflow space and terminal access need to remain practical after the new equipment is mounted. Do not alter covers or protective parts merely to apply a different temperature figure.
VFD-M manual and lifecycle reference
Delta’s current VFD-M product page identifies the series as discontinued and names ME300 and MS300 as successor directions. It does not provide a one-to-one replacement map for the models listed here.
To request a quotation from WOOLARS, select the required complete code and quantity. If your request is based on motor requirements rather than an existing code, include the motor nameplate and available supply. Identify an alternative-series request separately so its configuration is not confused with an order for the original VFD-M.