Delta CH2000 AC Motor Drives
Specify your Delta CH2000 heavy-duty drive by complete model code. Find frame references below and include the load cycle and braking arrangement with your inquiry.
- VFD007CH43A-21
- VFD015CH43A-21
- VFD022CH43A-21
- VFD055CH43A-21
- VFD075CH43A-21
- VFD110CH43A-21
- VFD150CH43A-21
- VFD300CH43A-21
- VFD370CH43S-21
- VFD450CH43A-00
- VFD1100CH43A-00
- VFD1600CH43A-21
WOOLARS supplies Delta CH2000 AC motor drives for industrial purchasing and replacement inquiries. The CH2000 is Delta’s heavy-duty vector-control drive family. This page covers 18 complete model references and the information needed to specify a drive for a demanding load.
Start with the machine duty, not just motor power
A request for a Delta CH2000 inverter should describe what the machine does during starting, running and stopping. For example, a lifting-axis inquiry needs to distinguish lifting and lowering from trolley travel. A motor power figure alone does not describe the load cycle or stopping requirement.
For an existing installation, send the drive and motor nameplates, fitted option-card codes and a parameter backup if available. For a new project, include supply details, motor rated current, peak-load duration, starts per hour and required acceleration/deceleration times. These details help make a quotation specific to the application.
Delta CH2000 VFD model references
The following complete codes appear in Delta’s ordering table. The frame column is a drawing reference, not a statement that drives sharing a frame are electrically interchangeable.
Frames A–C
| Complete model | Catalog frame |
|---|---|
| VFD007CH43A-21 | A |
| VFD015CH43A-21 | A |
| VFD022CH43A-21 | A |
| VFD037CH43A-21 | A |
| VFD055CH43A-21 | A |
| VFD075CH43A-21 | B |
| VFD110CH43A-21 | B |
| VFD150CH43A-21 | B |
| VFD220CH43A-21 | C |
| VFD300CH43A-21 | C |
Frames D0–G
| Complete model | Catalog frame |
|---|---|
| VFD370CH43S-21 | D0-2 |
| VFD450CH43A-00 | D1 |
| VFD550CH43A-00 | D1 |
| VFD750CH43A-00 | D1 |
| VFD900CH43A-00 | E1 |
| VFD1100CH43A-00 | E1 |
| VFD1320CH43A-21 | F2 |
| VFD1600CH43A-21 | G2 |
Source: Delta CH2000 English catalog, Ordering Information, printed page 44. This is this page’s model selection, not the full series range or a stock list.

Delta Drive Keypads and Open Terminal Compartments
Check the braking package separately
Delta lists built-in braking choppers for frames A–C. For the D0/D configurations listed here, the chopper is optional; the catalog also lists it as optional for frame E and above. A braking chopper and a braking resistor are different items: do not assume that ordering the drive includes the complete braking package.
When replacing a drive, record the existing braking unit and resistor labels and photograph the wiring arrangement. For a new installation, provide the stopping time and operating cycle for application-specific sizing. Do not select a resistor or change a mechanical holding-brake arrangement from the drive model alone.
Preserve the feedback and cabinet requirements
Record the encoder type, feedback-card model, network-card model and control arrangement if fitted. A request for a Delta CH2000 AC drive should state which existing options must be retained; series membership alone does not establish option compatibility.
Use the exact model’s dimension drawing when checking mounting, cable access and ventilation. Keep the complete suffix on the inquiry: an alternative ending in a different code needs its own installation and electrical review.
Request a CH2000 quotation from WOOLARS
Use Get A Quote or Live Chat to send the complete model, quantity and destination. Add the machine-duty details above when sizing a new drive, or the nameplate and fitted-option information for a replacement. Please identify any requested alternative separately from the original model.